RS-232 SERIAL CONTROL COMMANDS
#LOEDIDTOLO Function
The #LOEDIDTOLO function loads the speci ed EDID le to a speci ed local
input.
Syntax:
#LOEDIDTOLO param1 param2
Parameters:
param1 Echo mode [0 - 1]
Value Meaning
0 Semi echo mode
1 Full echo mode
param2 EDID size [1 - 2]
Value Meaning
1 128 byte EDID
2 256 byte EDID
#PRBAEDID Function
The #PRBAEDID function reads the EDID le from the speci ed bank and sends
it to the serial port.
Syntax:
#PRBAEDID param1 param2
Parameters:
param1 EDID bank offset [1 - 7]
param2 File type [0 - 1]
Value Meaning
0 .BIN le
1 .TXT le