RS-232 SERIAL CONTROL COMMANDS
#PRDSEDID Function
The #PRDSEDID function reads the downstream EDID and sends it to the serial
port.
Syntax:
#PRDSEDID param1
Parameters:
param1 File type [0 - 1]
Value Meaning
0 .BIN le
1 .TXT le
#PRLOEDID Function
The #PRLOEDID function reads the local EDID and spools it to the serial port.
Syntax:
#PRLOEDID param1
Parameters:
param1 File type [0 - 1]
Value Meaning
0 .BIN le
1 .TXT le