Gefen EXT-DVI-16416 User Manual

Browse online or download User Manual for Serial switch boxes Gefen EXT-DVI-16416. Gefen EXT-DVI-16416 User's Manual [en]

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1

www.gefen.com

Page 2 - ASKING FOR ASSISTANCE

7FRONT PANEL DISPLAYMAIN DISPLAY The Main Display of the 16x16 DVI Matrix is a 16 character 2 line display. This display will show the standby screen

Page 3 - CONTENTS

8FRONT PANEL DISPLAYROUTING To route sources to a display:Starting at the standby screen, press the SELECT button. The display selection screen will n

Page 4 - INTRODUCTION

9121 LED Button Press IndicatorThis LED will activate momentarily upon each button press. This visual indicator is to inform the user that a command

Page 5 - OPERATION NOTES

10IR Code Dip SwitchesEmpty Battery SlotTo use the RMT-16416IR remote, remove the battery cover on the back of the remote to reveal the battery compar

Page 6 - FEATURES

11Remote Channel 1:Default1 2Remote Channel 2:1 2Remote Channel 3:1 2Remote Channel 4:1 2Left: Picture of the opened rear battery comp

Page 7 - PANEL LAYOUT

12Invoking Standby ModeTo place the 16x16 DVI Matrix into Stand-by mode, simultaneously press and hold the SELECT and CANCEL buttons for 5 seconds, th

Page 8 - PANEL DESCRIPTIONS

13EDID MANAGEMENT FEATUREEDID. What is it and what is it used for?Under normal circumstances, a source device (digital and analog) will require inform

Page 9

14RS-232 SERIAL CONTROL INTERFACEWhat features are available via the RS-232 serial communications port?The GefenPRO 16x16 DVI Matrix can accept comman

Page 10 - MAIN DISPLAY

15RS-232 SERIAL CONTROL COMMANDSRS-232 FeaturesRS-232 remote functions are used to control of this product’s features. Features include input to outpu

Page 11 - ROUTING

16RS-232 SERIAL CONTROL COMMANDSS CommandThe S command routes a single input to all 16 DVI outputs.Syntax:s param1Parameters:param1 Input [0 - 1

Page 12

ASKING FOR ASSISTANCETechnical Support:Telephone (818) 772-9100 (800) 545-6900Fax (818) 772-9120Technical Support Hours:8:00 AM to 5:00 PM Monda

Page 13 - Empty Battery Slot

17RS-232 SERIAL CONTROL COMMANDSF CommandThe F command returns the state of pin 14 of the DVI inputs.Syntax:fParameters:NoneNotes:“High” is returned i

Page 14

18RS-232 SERIAL CONTROL COMMANDSEDID ManagementFunction Description#EDIDDSTOLO Read downstream EDID and stores into a Local EDID#EDIDDSTOBA Read downs

Page 15 - STANDBY MODE FEATURE

19RS-232 SERIAL CONTROL COMMANDS#EDIDDSTOBA FunctionThe #EDIDDSTOBA function reads the downstream EDID and stores it to a specifi ed EDID bank.Syntax:#

Page 16 - EDID MANAGEMENT FEATURE

20RS-232 SERIAL CONTROL COMMANDS#EDIDDETOLO FunctionThe #EDIDDETOLO function stores the Default EDID in any Local EDID.Syntax:#EDIDDETOLO param1 param

Page 17

21RS-232 SERIAL CONTROL COMMANDS#PRDSEDID FunctionThe #PRDSEDID function reads the downstream EDID and sends it to the serial port.Syntax:#PRDSEDID pa

Page 18 - Commands

22RS-232 SERIAL CONTROL COMMANDS#PREDIDST FunctionThe #PREDIDST function prints a table that contains details relating to the Local EDID source and th

Page 19

23RS-232 SERIAL CONTROL COMMANDSIP Confi gurationFunction Description#SIPADD Specifi es a new IP address#SNETMASK Specifi es a new net mask#SGATEWAY Spec

Page 20

24RS-232 SERIAL CONTROL COMMANDS#SNETMASK FunctionThe #SNETMASK function specifi es a new net mask.Syntax:#SNETMASK param1 param2 param3 param4Paramete

Page 21 - EDID Management

25RS-232 SERIAL CONTROL COMMANDS#SPORT FunctionSpecifi es a new port.Syntax:#SPORT param1Parameters:param1 Port [0 - 255]Notes:A reboot is require

Page 22

26RS-232 SERIAL CONTROL COMMANDSGeneral FunctionsFunction Description#FADEFAULT Reset Matrix to default settings#RMTIRADD Set the remote IR channel#MA

Page 23

CONTENTS1 Introduction2 Operation Notes3 Features4 Panel Layout5 Panel Descriptions6 Connecting And Operating The 16x16 DVI Matrix7 Front Panel Disp

Page 24

27RS-232 SERIAL CONTROL COMMANDS#MASKOUT FunctionThe #MASKOUT function allows blanking of selected outputs.Syntax:#MASKOUT param1 param2Parameters:par

Page 25

28RS-232 SERIAL CONTROL COMMANDS#STBYMODE FunctionThe #STBYMODE places the Matrix in stand-by mode. Stand-by mode reduces power consumption.Syntax:#S

Page 26 - IP Confi guration

29IP CONTROL - MAIN PAGEThe 16x16 DVI Matrix supports IP based control via an IP Control. To access this feature an IP address, subnet, gateway, and p

Page 27

30IP CONTROL - MANAGE EDIDMANAGE EDIDThe Manage EDID page is used to see the status of the EDID saved in the LOCAL storage location for each input. Th

Page 28

31IP CONTROL - MANAGE EDIDSET INPUT TO DEFAULT EDID Pressing the “SET INPUT TO DEFAULT EDID” button will display additional options. The following pag

Page 29 - General Functions

32IP CONTROL - MANAGE EDIDCOPY EDID Pressing the “COPY EDID” button will display additional options. The following page will open.On this page, the us

Page 30

33IP CONTROL - MASKINGMASKINGThe Masking page is used to hide an output from displaying any video. From this page, all outputs can be set to “Active”

Page 31

34IP CONTROL - IP CONFIGURATIONIP CONFIGURATIONThe IP Confi guration page is used to set the IP settings that will be used to access the unit using IP

Page 32 - IP CONTROL - MAIN PAGE

35IP CONTROL - BACKUP/RESTORE & POWER MANAGEMENTBACKUP/RESTOREThe Backup/Restore page is used to backup and restore complete setup confi gurations.

Page 33 - IP CONTROL - MANAGE EDID

36Switching and Masking without the Web InterfaceThe Gefen 16x16 DVI Matrix uses HTML form attributes to communicate to the box. It uses the ‘method’

Page 34 - SET INPUT TO DEFAULT EDID

1Congratulations on your purchase of the 16x16 DVI Matrix. Your complete satisfaction is very important to us.GefenGefen delivers innovative computer

Page 35 - COPY EDID

37Switching TableInput / Output Port Value10213243546576879810 911 A12 B13 C14 D15 E16 FExamplesSingle Outputhttp://192.168.0.70/cgibin.shtml?a=s&

Page 36 - IP CONTROL - MASKING

38MaskingWhen masking output ports, there are two states: Active and Masked. Multiple ports or all ports can be masked with a single command. It is p

Page 37 - IP CONTROL - IP CONFIGURATION

39Masking CommandMasking Command ValueActivate 0Mask 1Exampleshttp://192.168.0.70/cgibin.shtml?a=m&o0=1 *Masks Output 1. If the masking command va

Page 38 - POWER MANAGEMENT

40FIRMWARE UPDATEFIRMWARE UPDATE PROCEDURETo Begin the update procedure the unit’s Boot Loader must be activated. To activate the Boot Loader please f

Page 39 - IP CONTROL

41FIRMWARE UPDATEFollow the on-screen instructions to complete the fi rmware update process:1. Press [1] on the computer keyboard to begin downloading

Page 40

42WARNING MESSAGESFan FailureThe 16x16 DVI Matrix uses an internal fan to maintain a stable operating temperature in various environments. In the cas

Page 41

43Critical MalfunctionsTemperature FailureIf the measured system temperature exceeds 85° C, the following message will be displayed on the LCM:Power F

Page 42

44Video Amplifi er Bandwidth ... 165 MHz per channelSingle Link Range ...

Page 43 - FIRMWARE UPDATE

45Gefen warrants the equipment it manufactures to be free from defects in material and workmanship.If equipment fails because of such defects and Gefe

Page 44

46lwIP is licensed under the BSD licence:Copyright (c) 2001-2004 Swedish Institute of Computer Science. All rights reserved.Redistribution and use in

Page 45 - WARNING MESSAGES

2READ THESE NOTES BEFORE INSTALLING OROPERATING THE 16X16 DVI MATRIX• The 16x16 DVI Matrix will not pass HDCP content.• There is no internal scaling

Page 48 - WARRANTY

3Features• Increases productivity by providing access to 16 displays from any 16 computers.• Web-based control switching• Maintains beautiful, shar

Page 49 - LICENSING

4Front PanelBack Panel43PANEL LAYOUT5217869101112

Page 50

5PANEL DESCRIPTIONS1 Main LCD DisplayThis 2 line 16 character display will display status information and is also used to manage the display/source r

Page 51

6How to Connect the 16x16 DVI Matrix1. Connect up to 16 DVI source devices to the DVI inputs on the rear panel of the 16x16 DVI Matrix using DVI cabl

Comments to this Manuals

No comments